Control Core

CERBERUS / P12 · Modular internals
Interactive 3DConcept study
Service & display
CUTAWAY SECTIONP12 exterior / conceptual interior
HANDLEBAYONET
Drag to orbit · Scroll to zoom
P12 reference · 39.30 × Ø7.78 mm
Reference & limitations 5 end routes unresolved

3D routing status

79 visible routing guides cleared the assembled solid-geometry check. 5 unresolved paths are withheld from the 3D view and listed below. Their functional connections remain in the wiring diagram; they are not verified physical routes.

Connections still needing a physical route
  • stack negative / neck transition TBD: End transition or interface path has not been geometrically routed.
  • stack positive / neck transition TBD: End transition or interface path has not been geometrically routed.
  • Protected auxiliary feed to front regulator / leg 1 logical guide: End transition or interface path has not been geometrically routed.
  • Protected auxiliary feed to front regulator / leg 2 logical guide: End transition or interface path has not been geometrically routed.
  • Shared isolated COM link to front monitor controller / neck transition TBD: End transition or interface path has not been geometrically routed.

There is no artificial wire-thickness expansion. Endpoint contact regions and connector internals are conceptual allowances, not selected or rated terminations.

Electrical reference / approved concept connectivity

One service channel / separate power and communication lanes

This panel explains the approved 9S61P connection scheme and proposed fixed-dock service layout. One trapezoidal trough has no internal divider. It carries distinct POWER and ISOLATED COM harness courses. Short cartridge-local connections meet the core-mounted docks; long power cables and the communication harness stay with the core when a cartridge is removed. This remains an engineering discussion reference, not a rated construction schematic.

APPROVED CONCEPT — 9S61P with individual cell fusible-link allocations.Each cartridge contains 61 parallel cells; nine cartridges connect in series. Each positive cell tab includes an approved fusible-link allocation. Device selection, link interruption performance, fault coordination and actual vehicle loads remain to be verified.
32.4 Vnominal stack voltage
37.8 Vassuming a 4.2 V per-cell charge ceiling
240.5 Ahnominal capacity: 37 × 6.5 Ah
7.7922 kWhnominal cell-energy sum; usable energy unvalidated

Fixed local docks / every cartridge remains a separate service unit

Red and slate distinguish the series power circuit. Blue shows the separate isolated-monitoring harness course in the same overall channel. A shared route does not join cartridge grounds or make the power circuit parallel. Line widths are graphical, not cable dimensions or ampacity. Scroll horizontally on a small screen.

Nine 9S61P cartridges with fixed docks in a shared service channel Each cartridge connects locally to its fixed dock. Eight core-mounted series jumpers link adjacent power terminals. A dedicated return and the stack-positive end connect to main protection and the base plug. The isolated communication harness occupies a separate section of the same trough. Blue link segments do not imply an unisolated multidrop bus or common cartridge ground. 9S61P series power circuit / local cartridge connections to D01–D09 Cartridge monitoring is powered in its own protected 1S domain; voltage, temperature and fuse-status leads stay local. ONE CORE-MOUNTED SERVICE TROUGH / proposed docking interfaces and long harnesses remain with the core POWER lane / eight separate series jumpers, never a common parallel rail ISOLATED COM lane / paired-harness course; electrical interface and protocol remain unselected C0161 cells / 1S61Plocal monitor / T / fuse D01 fixed−+COM* J01 link C0261 cells / 1S61Plocal monitor / T / fuse D02 fixed−+COM* J02 link C0361 cells / 1S61Plocal monitor / T / fuse D03 fixed−+COM* J03 link C0461 cells / 1S61Plocal monitor / T / fuse D04 fixed−+COM* J04 link C0561 cells / 1S61Plocal monitor / T / fuse D05 fixed−+COM* J05 link C0661 cells / 1S61Plocal monitor / T / fuse D06 fixed−+COM* J06 link C0761 cells / 1S61Plocal monitor / T / fuse D07 fixed−+COM* J07 link C0861 cells / 1S61Plocal monitor / T / fuse D08 fixed−+COM* J08 link C0961 cells / 1S61Plocal monitor / T / fuse D09 fixed−+COM* C01− / dedicated stack returnC09+ / stack positive Existing monitoring / compute functionsHost-side isolated communication interface TBDNo common cartridge ground is implied. Approved main function allocationProtection / service disconnect / protected returnPole arrangement and device ratings unassigned. W-OUT−W-OUT+ Base plug / rover powerMotor drivers, cameras and rover radios COM*: functional isolated-link allocation, not a selected transceiver.Blue segments show one shared harness course, not a specifiedmultidrop circuit or a direct electrical join between local grounds. Dock geometry guides the separate harness courses.They do not establish galvanic isolation or EMI shielding.Protected rails also supply the regulator / PCB / SRD.Motor power bypasses the compute PCB.

Inside each cartridge / short local connections

37 cell terminal pairs / individual positive fusible links→Positive / negative collection layers→Approved fuse / isolation function→Short local leads→Fixed dock D01–D09 / separate power and COM contacts

Positive cell terminals connect through individual fusible-link allocations into the positive collection layer; negative terminals connect to the separate negative collection layer. The monitoring allocation uses its own cartridge-local protected supply. Voltage, representative cell-temperature and fuse-status connections stay short inside that cartridge, then reach its local dock communication interface. They do not connect directly to one common stack supply or join local cartridge grounds. Busbar material, joining process, insulation, vent clearance and terminal stack allowance remain to be engineered.

Individual cell fusible links approved / ratings unassigned

F-C01-01 through F-C09-37 identify 549 individual positive cell-link allocations. The cartridge-output fuse remains a separate function. Cell-link dimensions, opening current/time, interrupt rating and coordination are unassigned; these symbols do not establish thermal-runaway containment.

Auxiliary power / W-AUX+ and W-AUX−

Protected P+ / P− rails→Approved regulated supply→Compute PCB→On-PCB SRD

Regulator input/output range, power, grounding and isolation are unassigned. The high-current rover output bypasses the PCB.

Data / D-SRD

Core PCB / SRD⇄Wireless rover endpoint⇄Rover backhaul radio⇄Central Supervisor

The base plug is the power interface. The local SRD link carries configurable digital I/O; the rover provides the Supervisor radio link.

Connection legend / separate power and return conductors

Each positive cell terminal → its individual fusible link → the cartridge positive collection busbar → cartridge fuse/isolation → the short series jumper network → main protection/service disconnect → base-plug positive. There are 37 individual cell links in each parallel group and 549 across the nine cartridges; they are parallel cell branches, not 549 fuses in one series conductor.

Separate negative collection busbars complete each cartridge connection. C01− provides the stack-negative end through the protected return allocation to the base-plug negative. The return rail is a dedicated conductor, not the chassis or core casing. Individual cell fusible links and cartridge fuses serve different fault paths; neither is a demonstrated guarantee against thermal runaway or propagation.

Shared-channel proposal: a trapezoidal trough has a POWER section for two 8 mm outside-diameter packaging targets and a distinct ISOLATED COM section for the paired monitoring-harness allowance. Long harnesses and docks stay core-mounted; cartridge-local leads end at D01–D09. There is no internal divider. Harness spacing, retention, electrical isolation and electromagnetic performance remain engineering requirements. Actual dock mating direction, retention, contact layout, feedthroughs, cable gauge, end-neck transitions and bend radius remain unvalidated.

ReferenceConnection / functionState
C01–C0961-cell cartridges, including local monitoring, temperature sensing and approved fuse/isolation allocations1S61P connectivity approved; hardware provisional
J01–J08C01+ → C02− through C08+ → C09−; eight fixed-dock series jumpers; no common parallel power railPolarity keying, connector design and ratings unassigned
W-P+ / W-P−C09+ / C01− to the main protection and service-disconnect function32.4 V nominal; fault-current and switching design pending
W-OUT+ / W-OUT−Protected power rails to the base plug and rover distribution69.3 A continuous / 136 A peak low-voltage load case; gauge and pinout unassigned
W-AUX+ / W-AUX−Protected rails to regulator, then PCB and SRD electronics60 W combined electronics allowance; regulated voltage unassigned
M01–M09 / T01–T09Per-cartridge monitoring/protection and cell-temperature functionsSignal protocol, local reference and floating-domain isolation unresolved
D-SRDPCB ⇄ local SRD ⇄ rover; rover backhaul ⇄ SupervisorFunctional communications path; no RF performance claim

Provisional vehicle electrical load case

Chosen for this reference: six brushless wheel motors at 250 W electrical input each continuously, or 500 W each for a 10-second example peak, plus 60 W total core/rover electronics. These are assumed battery-side demands, not motor specifications or a prediction from rover mass. Several hundred kilograms on the Moon does not establish power without speed, terrain, slope, wheel radius, gearing and traction data.

Reference loadContinuous10-second example peak
Six wheel motor electrical inputs6 × 250 W = 1,500 W6 × 500 W = 3,000 W
Electronics allowance60 W60 W
Total battery-side budget1,560 W3,060 W
At 37.8 V calculation point41.3 A81.0 A
At 32.4 V nominal48.1 A94.4 A
At 22.5 V theoretical low boundary69.3 A136.0 A

Current is P/V before wiring losses. The 22.5 V point is nine times 2.5 V for sensitivity analysis; it is not a selected operational cutoff or a recommended discharge strategy. This budget excludes excavation/drum power, heaters, charging, regenerative braking and additional conversion losses. The 10-second interval is an assumed comparison duration, not a validated duty cycle.

Main power conductor comparison / not an ampacity selection

Comparison basis: copper at 20°C, resistivity 0.017241 Ω·mm²/m and 2.0 m total current-path conductor length. R = ρL/A; drop = IR; heating = I²R. Actual path length, eight series jumpers, contacts, fusible links and busbars add resistance.

Copper areaEquivalent solid bare diameterResistance / 2 mDrop at 136 AResistive loss at 136 A
10 mm²3.57 mm3.448 mΩ0.469 V63.8 W
16 mm² comparison basis4.51 mm2.155 mΩ0.293 V39.9 W
25 mm²5.64 mm1.379 mΩ0.188 V25.5 W

No row establishes allowable current. Strand packing and insulation increase diameter. An 8 mm insulated outside diameter for the 16 mm² comparison is a packaging target only, not a selected or rated cable specification. A single trapezoidal channel in the cartridge crescent space reserves distinct POWER and ISOLATED COM sections. Geometry, wall continuity and cartridge extraction are checked separately from electrical performance. The side-by-side paired communication course, end-neck transitions, dock/feedthrough details and cable bend radius still require coordinated design. Power lines in the 3D reference explain connectivity; a proposed channel or cable envelope does not establish installed cable performance.

Vacuum, insulation, wire temperature, bundling, mounting heat paths and termination temperatures determine the needed thermal derating. At 69.3 A, the same 16 mm² / 2 m copper example dissipates 10.4 W before connections. Hotter copper increases resistance. The actual cable, connector and fuse set still requires coordinated electrical, thermal and packaging design.

Sources: Copper IACS resistivity · NASA wire derating and thermal modelling.

Shared route / electrically separate domains

The user-requested simplification is mechanical: local cartridge functions connect at their nearby dock, and the paired isolated communication harness follows the power harness in another section of the same overall trough. Isolation hardware and the actual link architecture remain unselected. The channel has no divider; electrical isolation and immunity to motor switching noise still require the appropriate interface and installation design.

Short local monitor branches and a shared paired-harness course replace the earlier nine long individual blue routes. A future isolated daisy chain would use successive point-to-point segments; an isolated multidrop bus would require a different selected interface. This reference intentionally specifies neither circuit. Cable construction, spacing, twisting, termination and electromagnetic testing remain engineering inputs.

Architecture examples only: TI isolated monitor-chain architecture · ADI isolated twisted-pair link description. These examples do not select devices suitable for the present 1S-per-cartridge arrangement.

Inputs needed before this becomes a rated wiring reference

Confirm the 9S operating voltage window and actual continuous/peak motor and electronics loads; real peak duration and regeneration/charging behaviour; cable lengths and permissible voltage drop; insulation, connector and thermal conditions; selected protection devices and fault-interruption requirements. The main cable size cannot be derived from the cell count or a cell’s discharge-current listing alone.

Service is de-energized: isolate and verify power off, unmate the selected cartridge at its proposed dock, then open the housing or lift the cartridge. The fixed dock, long power harness and COM harness remain with the core. The dock is a mechanical/electrical interface allocation, not a catalog connector or live mating design. Hot swapping, a communication bypass with a dock disconnected, and continued operation with a removed cartridge are not claimed.

Context: Molicel M65A nominal cell data · NASA on parallel-cell isolation and propagation · TI on battery monitoring functions. These sources do not validate this proposed pack.